Product Overview
Suitable Applications | Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base – T (Gigabit Ethernet), 100 Base – T, 10 Base – T, FDDI, ATM |
---|
Physical Characteristics (Overall)
CONDUCTOR
ELEMENT | AWG | STRANDING | MATERIAL | NO. OF PAIRS |
---|---|---|---|---|
Individual pair | 23 | Solid | BC – Bare Copper | 4 |
Conductor Count | 8 |
---|---|
Total Number of Pairs | 4 |
INSULATION
ELEMENT | TYPE | MATERIAL | NOMINAL DIAMETER |
---|---|---|---|
Individual pair | Dielectric | PE – Polyethylene | 0.96 mm |
Bonded-Pair | No |
---|
COLOR CHART
NUMBER | COLOR |
---|---|
Pair 1 | White/Blue & Blue |
Pair 2 | White/Green & Green |
Pair 3 | White/Orange & Orange |
Pair 4 | White/Brown & Brown |
CABLING
DESCRIPTION | FILLER |
---|---|
4 pairs twisted together | Cross Web of Polyolefin |
OUTER JACKET MATERIAL
MATERIAL | NOMINAL DIAMETER | DIAMETER +/- TOLERANCE |
---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 5.4 mm | 0.3 mm |
Construction and Dimensions
Min Elongation at Breakof Conductors | 10 % |
---|---|
Min Elongation at Breakof Insulation | 100 % |
Min Elongation at Breakof Jacket | 100 % |
---|---|
Min Tensile Strength of Jacket | 9 MPa |
Electrical Characteristics
CONDUCTOR DCR
MAX. CONDUCTOR DCR | MAX DCR UNBALANCED BETWEEN PAIRS [%] | MAX. DCR UNBALANCED WITHIN PAIR [%] |
---|---|---|
95 Ohm/km | 4 % | 2 % |
CAPACITANCE
MAX. CAPACITANCE UNBALANCE | MAX. MUTUAL CAPACITANCE |
---|---|
1,600 pF/km | 56 pF/m |
IMPEDANCE
NOMINAL CHARACTERISTIC IMPEDANCE |
---|
100 Ohm |
DELAY
MAX. DELAY SKEW | NOMINAL VELOCITY OF PROPAGATION (VP) [%] |
---|---|
40 ns/100m | 70% |
Table Notes | Limits below 4 MHz are for information only. Reference standard: IEC 61156-5 |
---|---|
General Electrical Parameters Notes | Reference standard: ISO/IEC 61156-5 |
Coupling Attenuation Class | Type III |
---|---|
Segregation class according EN50174-2 | a |
CURRENT
MAX. RECOMMENDED CURRENT [A] |
---|
1.5 Amps per Conductor |
VOLTAGE
VOLTAGE RATING [V] |
---|
72 V |
Temperature Range
Installation Temp Range | 0°C To +50°C |
---|---|
Operating Temp Range | -30°C To +60°C |
Mechanical Characteristics
Bulk Cable Weight | 37 kg/km |
---|---|
Max. Pull Tension | 80 N |
Min. Bend Radius During Installation | 46 mm |
Min Bend Radius During Operation | 23 mm |
Standards
ISO/IEC Compliance | ISO/IEC 11801-1 |
---|---|
CPR Euroclass | Eca |
CENELEC Compliance | EN 50173-1 |
Data Category | Category 6 |
ANSI Compliance | ANSI/TIA 568.2-D (2018) |
IEEE Compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
Applicable Environmental and Other Programs
Environmental Space | Indoor – Euroclass Eca |
---|---|
EU RoHS Compliance Date (yyyy-mm-dd) | 2004-01-01 |
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2 |
---|---|
Burning Load | 455 kJ/m |
IEC 60754-1 – Halogen Amount | Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity | 2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH | 4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance | 60% |
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
---|
History
Update and Revision | Revision Number: 0.261 Revision Date: 08-27-2021 |
---|