Product Overview
| Suitable Applications | OSP-Outside Plant, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, HDBaseT |
|---|---|
| Patent | This product has one or more applicable patents. |
Construction Details
CONDUCTOR
| AWG | STRANDING | MATERIAL | NUMBER OF PAIRS |
|---|---|---|---|
| 23 | Solid | BC – Bare Copper | 4 |
INSULATION
| MATERIAL | COLOR CODE |
|---|---|
| PO – Polyolefin | White & Blue, White & Orange, White & Green, White & Brown |
| Bonded-Pair | No |
|---|
INNER JACKET MATERIAL
| MATERIAL | NOM. DIAMETER | RIPCORD |
|---|---|---|
| PE – Polyethylene | 0.260 in | No |
| Waterblocking | Gel Filled |
|---|
OUTER JACKET MATERIAL
| SEPARATOR MATERIAL | MATERIAL | NOM. DIAMETER | RIPCORD |
|---|---|---|---|
| Center Member (Patented X-Spline®), EquiBlock™ Barrier Technology | PE – Polyethylene | 0.355 in | Yes |
Electrical Characteristics
ELECTRICALS
| MAX. CONDUCTOR DCR | MAX. DCR UNBALANCE | MAX. DCR UNBALANCED BETWEEN PAIRS [%] | MAX. CAPACITANCE UNBALANCE | NOM. MUTUAL CAPACITANCE |
|---|---|---|---|---|
| 82 Ohm/km | 3% | 5% | 45 pF/100m | 17 pF/ft |
DELAY
| FREQUENCY [MHZ] | MAX. DELAY | MAX. DELAY SKEW | NOM. VELOCITY OF PROPAGATION (VP) [%] |
|---|---|---|---|
| 100 MHz | 537.6 ns/100m | 45 ns/100m | 65% |
HIGH FREQ
VOLTAGE
| NON-UL VOLTAGE RATING |
|---|
| 300 V |
Mechanical Characteristics
TEMPERATURE
| OPERATING | INSTALLATION | STORAGE |
|---|---|---|
| -40°C To +75°C | -40°C To +60°C | -40°C To +75°C |
BEND RADIUS
| INSTALLATION MIN. |
|---|
| 3.75 in |
| Max. Pull Tension | 25 lbs |
|---|---|
| Bulk Cable Weight | 48 lbs/1000ft |
Standards and Compliance
| Environmental Suitability | Outdoor, Outdoor, Sunlight Resistance |
|---|---|
| ICEA Compliance | S-116-732-2013, S-56-434, S-99-689, S-100-685 |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| NEMA Compliance | ANSI/NEMA WC-66 |
| Data Category | Category 6A |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
| CENELEC Compliance | Segregation class according EN50174-2=a |
| CPR Euroclass | Fca |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | Verified Channel/Category 6A |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1. |
|---|
History
| Update and Revision | Revision Number: 0.300 Revision Date: 08-27-2021 |
|---|
Part Numbers
| ITEM # | COLOR | UPC |
|---|---|---|
| OSP6AU 0101000 | Black | 612825378266 |