PHYSICAL DESCRIPTION
Products multi mode Fiber optic cable
Tube Filling Compound Thixotropic jelly
Fiber Type 50/125 OM3
Tube material PBT ( Polybutylene Terephthalate)
Armour Corrugated steel tape
Packing Detail
Fiber Count 6,8,12,24,
Tube Outer/Inner Diameter(mm) 3.0/2.0 ±
Cable Diameter(mm) 7.2*-12
Cable Weight(kg/km) 45±
Length/ Drum 2000 m Drum ±5%
Ripcord Polyester cord
Outer Jacket PE,MDPE, LSZH
Mechanical and Environmental Properties
Physical tests Value Standard
Tensile Strength 2700 N (during Installation)
1700 N (during Operation) IEC 60794-1-E1
Impact Resistance 10J, 3 impacts IEC 60794-1-E4
Crush Resistance 220 N/cm IEC 60794-1-E3
Temperature Cycling -40 to +70 °C IEC 60794-1-F1
Flame Retardancy According to IEC 60332-3 IEC 60332-3
Cable Bending Radius
Bend Radius (during installation) 20x cable diameter IEC 60794-1-2-E11A
Bend Radius (during Service) 10x cable diameter IEC 60794-1-E11
Repeating Bending 20x cable diameter IEC 60794-1-E6
Temperature Range)
Operation Temperature -40 to +70 C
Storage and Transportation Temperature -40 to +70 C IEC 60794-1-2-F1
Installation Temperature -30 to +60 C
Optical Characteristics
Fiber type 50/125 μm MM OM2 50/125 μm MM OM3 50/125 μm MM OM4
Attenuation (max)
850 nm 3.5 dB/km 3.5 dB/km 3.5 dB/km
1300 nm 1.5 dB/km 1.5 dB/km 1.5 dB/km
Bandwidth (Laser EMB)
850 nm 2000 MHz.km 2000 MHz.km
1300 nm 500 MHz.km 500 MHz.km
Bandwidth (Overfilled)
850 nm 700 MHz.km 1500 MHz.km 3500 MHz.km
1300 nm 500 MHz.km 500 MHz.km 500 MHz.km
Numerical Aperture 0.200±0.015 0.2±0.015 0.2±0.015
Core Diameter 50 ± 2 μm 50 ± 2 μm 50 ± 2 μm
Cladding Diameter 125 ± 1μm 125 ± 1μm 125 ± 1μm
Core/Clad Concentricity error ≤ 1 μm ≤ 1 μm ≤ 1 μm
Cladding non-circularity ≤ 0.7 % ≤ 0.7 % ≤ 0.7 %
Coating Diameter 242 ± 5 μm 242 ± 5 μm 242 ± 5 μm
Proof Test ≥ 100kpsi or 0.7GPa ≥ 100kpsi or 0.7GPa ≥ 100kpsi or 0.7GPa